Wind, solar and electricity price loading… Wind generation (latest available quarter-hour): loading… Solar generation (same quarter-hour): loading… PSE says the data cover sources both in and outside the balancing market. It does not say whether or how it counts rooftop panels. Installed capacity of prosumer photovoltaic panels: 13,735 MW – end of September 2026 (ARE, preliminary data). Official annual report: 13,089 MW – end of 2025 (URE, report of 25 Mar 2026).
Latest wind curtailment in the PSE report: loading… Electricity price (RCE): loading…

Source PSE · loading…

Night lights (2016 image) approximate activity and lighting – mainly street and building lights – not a measurement of electricity use.
What the markers mean

Capacity for new generators: loading…

Power plants: operating and large ones only (thresholds in “Sources and licences”)

Marker size = installed capacity, not current generation

Size examples: 100 MW – small square, 1,000 MW – medium, 5,000 MW – large.

Sources: GEM · OpenStreetMap · EMODnet · PSE

Poland at a glance loading…

loading…

    How much of what we have is running

      • Installed capacity is not available capacity: some units are under maintenance or in reserve.
      • Wind and solar run when the wind blows and the sun shines – a short bar means weather or time of day, not a breakdown.
      • “?” – In its report PSE gives a single capacity for wind (onshore and offshore), solar and other renewables – with no breakdown. The report also does not say whether or how this capacity includes rooftop panels. Hydro is not included here.
      • No bar: hydro, oil, waste and “other” – the PSE report gives no capacity for them that can be compared with generation.
      • The map shows only larger power plants, so the capacity total on the map (“Where from” tab) is smaller.

      Source PSE, KSE Report 2025 (Polish power system), Table 1.1

      RCE price
      loading…
      Life-cycle carbon footprint
      loading…
      Cross-border exchange (scheduled)
      loading…

      Source PSE · loading…

      processing and carbon intensity: SOURCE

      Methodology
      • Data source: PSE, report “his-gen-pal-sire” – electricity generation in Poland by fuel, every 15 minutes. PSE usually publishes it 30–45 minutes late, and the site retrieves data every 4 hours.
      • Cross-check: at every retrieval, wind and solar from this report must match (within 1 MW) a second PSE report (“his-wlk-cal”). If they don't, the previous data stays, with a badge. Last time: no data.
      • Shares: calculated from generation in Poland. We leave out pumped-storage plants – they store energy, they are not a source. Waste is not counted as renewable.
      • Life-cycle carbon intensity (g CO₂eq/kWh), SOURCE estimate based on IPCC: generation from each fuel × typical life-cycle emissions of a power plant, in CO₂ equivalent (CO₂eq) – IPCC medians, AR5 report, 2014. For fuels IPCC doesn't cover (lignite, oil, coal-derived gas, waste, “other”, “other renewables”), we made our own assumptions based on factors from KOBiZE (Polish National Centre for Emissions Management). In the quarter-hour we checked (20 Nov 2026, 12:00–12:15), the extreme variants of these assumptions – excluding lignite – changed the result by less than 3%. Electricity bought abroad is not included. Exactly now: no data.
      • KOBiZE's 553 kg CO2/MWh (2024) is a different measure: combustion emissions only, averaged over the whole year. We do not compare it directly with our estimate.
      • Scheduled cross-border exchange: scheduled exchange according to PSE (sum of two balances: swm_p + swm_np), not measured. “Importing” – power flows into Poland, “exporting” – out of Poland.